Part Number Hot Search : 
2SC57 BH7673 UGSP15D EXE8602 160808 15KPA78A FS020551 BYT53C
Product Description
Full Text Search
 

To Download DMR20-10-DCM-R-C Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  murata power solutions new dmr20-10-dcm self-powered, auto-ranging dc voltage monitors are designed to measure and display the outputs the most popular dc power systems. simply connect any 6 to 75v dc power source and these meters are fully opera- tionalno additional components or power sources are required. their large, 0.30"/7.6mm, bright led displays can be easily read from 10 feet away (3 meters). these auto-ranging meters accurately display dc voltages with 0.01v in the lo range (below 51v), or 0.1v resolution in the hi range (above 51 v). a built-in resettable fuse assures long term reliability. all dmr20-10-dcms employ a 13-bit a/d converter and precision metal-? lm resistors to achieve outstanding performance over an operating temperature range of C25 to +60c. the dmr20-10-dcm is housed in a rugged, round polycarbonate case that provides excel- lent protection against moisture, dust, shock and vibration. panel installation is straightfor- ward: using readily available tooling, simply drill and punch a 1.2 inch (30.5mm) diameter hole and anti-rotation notch, insert the meter and gasket into the panel, and securely fasten the meter using the supplied hex nut. the supplied hardware is designed to provide protec- tion to ip67/nema 6. ? operation and accuracy at inputs above or below these ranges are not speci? ed. ? when auto-range operation is enabled via jumper jp1 and vin is between 6v to 51v, the displayed resolution is 0.01v (i.e., the unit is in lo range). when vin is 51v and above, display resolution is 0.1v (i.e., the unit is in hi range). when the unit is in the hi range and vin drops below 49v, it will auto-range back to the lo range. ? when vin is between 75v and 80v, the display will alternate from dim to normal intensity at approximately one second intervals. when vin exceeds 80v, display will ? ash on and completely off at approximately one second intervals. continuous operation above 80v will permanently damage the meter and void its warranty. performance/functional speci? cations typical at ta = +25c, unless otherwise noted dc input (tb1) input voltage range ? +6 to +75vdc current consumption @vin = 75.0vdc: 7ma (max.) reverse polarity protection -100vdc (min.) performance sampling rate 2.5 readings/second resolution 0.01vdc in lo range; 0.1vdc in hi range accuracy @ +25c hi range ? 0.2v (typ.), 0.4v (max.) lo range ? 0.03v (typ.), 0.06v (max.) overrange indication ? see note 3 temperature drift 0.003v/c (typ.) mechanical dimensions 1.50"diameter x 1.08 depth" (38.1 x 27.4mm) display type four digit, led, 0.30" high (7.6mm) weight 0.6 ounces (18 grams) with nut and gasket case material polycarbonate terminal block torque 3.6 in-lbs (0.4 n-m) wire size and type 18-22awg (0.83-0.33mm 2 ) copper, solid or stranded wire insulation strip length 0.25" (6.4mm) environmental operating temperature C25 to +60c storage temperature C40 to +75c humidity (non-condensing) 0 to 85% ordering information DMR20-10-DCM-R-C 6 to 75vdc voltage monitor (red led) tooling dmr20-1-kp 1.2" (30.5mm) round knockout punch (no keying notch) dmr20-2-kp 1.2" (30.5mm) round knockout punch (with four keying notches) dmr20-3-kp 1/8" and 3/16" (3.2 and 4.7mm) key-notch nibbler tool note: an m30 x 1.5 nylon hex nut and epdm sealing gasket are supplied with each meter. the -c suf? x denotes rohs compliance. www.murata-ps.com www.murata-ps.com/support for full details go to www.murata-ps.com/rohs $ dmr20-10-dcm 2-wire, self-powered, auto-ranging dc voltage monitor mpm_dmr20-10-dcm.a01 page 1 of 4 nano features ? ? self-powered, requires only two connections ? ? auto-ranging 6 to 75vdc input range ? ? installs in round oiltight 1.20 inch (30.5mm) cutouts ? ? reverse polarity protected to C100vdc ? ? four-digit led display with overvoltage indication ? ? digital replacement for analog panel meters ? ? screw-style terminal block simpli? es installation ? ? self-resetting internal fuse for long-term reliability ? ? provides moisture resistance to ip67/nema 6 ? ? supplied with epdm rubber gasket and plastic hex nut ? ? panel knockout punches and tooling available
technical notes important! to ensure safe and reliable operation, dmr20-10-dcm dc voltage monitors must be installed and serviced by quali? ed technical personnel. contact murata power solutions if there is any doubt regarding installation or operation. 1. operating input range: the unit is shipped with auto-range jumper jp1 in the open position. with jp1 open, auto-range operation is disabled and the unit will display input voltages between +6 to +75vdc with a ? xed 0.1v resolution. changes to jp1s con? guration must only be made when the unit is off (de-energized). the unit will not recognize jp1 con? guration changes made with power applied to tb1. closing jumper jp1 (see figure 1) places the unit in the auto-range mode of operation. with auto-range enabled and vin between +6v to +51v, the displayed resolution is 0.01v (i.e., the unit is in lo range). when the unit is in lo range and vin is increased to +51v, it will auto- range to the hi range and display 0.1v resolution. when the unit is in hi range and vin drops below +49v, it will auto-range back to the lo range and display 0.01v resolution. operation below +6vdc will produce a noticeably dimmer display and accuracy is not guaranteed. continuous operation between +75 and +80vdc, while not recommended, will not adversely affect the unit. see the performance/functional speci? cations section for more information. 2. calibration: dmr20-10-dcm voltmeters are factory calibrated; there are no provisions for calibrating these meters in the ? eld. 3. panel installation: all electrical connections to dmr20-10-dcm must be made after the voltmeter is securely attached to the panel, and with the input dc input supply source de-energized (off). in high-vibration environments, adequate strain reliefs must be used on all supply wiring. see figure 2 for typical panel mounting details. tightening torque: the recommended tightening torque for the m30 x 1.5 plastic hex nut is 10 to 17 in-lbs (1.3 to 1.9 n-m). if a torque wrench is not available, this recommended range can be approximated by hand tightening the hex nut slowly until it just bottoms out against the panels rear sur- face. from this bottomed-out reference position, using a suitable tool, tightening the hex nut ? turn clockwise will produce approximately 10 in-lbs (1.3 n-m) of torque; tightening it 3/8 turn clockwise will produce approximately 17 in-lbs (1.9 n-m). check to make sure the housings anti-rotation key is aligned with the notches on both the panel and the gasket before tightening the hex nut. over tightening the hex nut will distort the rubber gasket and may damage the threads on both the nut and the housing, thereby compro- mising the installations mechanical integrity and its ability to protect against environmental effects. panel thickness: when using both the factory supplied epdm gasket and hex nut (the recommended standard installation method), the dmr20-10-dcm can be mounted in panels ranging from 0.032" to 0.250" (0.8 to 6.4mm) thick. when the gasket is not used, the panel thickness range is 0.075" to 0.325" (1.9 to 8.3mm). however, using the factory supplied hardware and tightening torque recommendations results in optimal resistance to vibration, and dust and moisture ingress. ! panel materials: acceptable panel materials include aluminum, mild steels, plastics, fr-4 pc-board (? berglass), and many other materials with a ? at matte surface on both sides of the cutout. the dmr-20-x-kp tools can be used with most panel materials except for stainless steel or other hardened metals. dmr20-10-dcm has passed vibration testing combined with tem- perature cycling while mounted to the materials noted above, using the speci? ed tightening torques. if the voltmeter will be mounted to extremely smooth or slippery surfaces, the user is advised to test the completed assembly under the environmental conditions expected in the end application. 4. input fusing and wiring : dmr20-10-dcm voltmeters contain an internal, self-resettable fuse. however, the supply wires connected to input terminals tb1s + and C terminals must be fused with an external, user supplied, 0.25a/300v time delay/time lag fuse, in accor- dance with applicable regulatory codes. all supply wiring must be rated for the voltages and currents they will conduct and comply with any code or application-mandated require- ments pertaining to the users speci? c installation. 300v, ul-rated hook-up wire suitable for the intended application is required. tb1 is to be used only for powering the meters internal circuitry; it must not be used to supply power to external loads. the recommended tb1 supply wire size is 18awg to 22awg (0.83mm 2 to 0.33mm 2 ) solid or stranded copper wire. the supply wires must be properly stripped and attached to tb1 such that their insulation is not pinched by the screw terminal. recommended insulation strip length is 0.25" (6.4mm). when using stranded wire, verify that there are no loose or stray strands that could potentially cause a short circuit across the dc supply input. 5. input polarity: the input terminal block tb1 is polarity sensitive, and connections to it must be made as shown in the mechanical speci? ca- tions section of this data sheet. however, intermittent or continuous application of reverse-polarity voltages up to C100v will not damage the meter. figure 1. jp1 con? gured for auto-range operation www.murata-ps.com/support dmr20-10-dcm 2-wire, self-powered, auto-ranging dc voltage monitor mpm_dmr20-10-dcm.a01 page 2 of 4 nano
mechanical specifications dimensions are in inches (mm). tolerances (unless otherwise speci? ed): .xx 0.02 (0.51) .xxx 0.010 (0.254) angles 2? components are shown for reference only. - + j1 tb1 1.50 (38.1) 0.98 (24.9) 1.18 (29.8) 0.655 (16.64) 0.55 (14) 0.080 (2.03) 0.10 (2.5) 0.062 (1.58) 0.100 (2.54) 1.210 (30.73) dc volts v recommended panel cutout figure 2. panel installation 3d models are available at www.murata-ps.com/en/3d/meters.html www.murata-ps.com/support dmr20-10-dcm 2-wire, self-powered, auto-ranging dc voltage monitor mpm_dmr20-10-dcm.a01 page 3 of 4 nano
notes murata power solutions, inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. the descriptions contained her ein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. speci? cations are subject to cha nge without notice. ? 2013 murata power solutions, inc. www.murata-ps.com/support murata power solutions, inc. 11 cabot boulevard, mans? eld, ma 02048-1151 u.s.a. iso 9001 and 14001 registered dmr20-10-dcm 2-wire, self-powered, auto-ranging dc voltage monitor mpm_dmr20-10-dcm.a01 page 4 of 4 nano


▲Up To Search▲   

 
Price & Availability of DMR20-10-DCM-R-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .